LMK Technologies - Breaking New Ground without Breaking Any Ground

  • Lateral
  • Mainline
  • Manhole
  • Vac-A-Tee®
  • Insignia™
  • Potable Water
  • Equipment
  • LMK News
  • Events
  • LMK Story
  • Contact
  • Home
  • Lateral
    • Connection Sealing
    • T-Liner®
      • Video
      • Brochure
      • Powerpoint
      • FAQ
      • Installation Specs
      • ASTM Standards
      • Submittal
      • Articles
    • Shorty™
      • Brochure
      • FAQ
      • Installation Specs
      • ASTM Standards
      • Submittal
    • Stubby™
      • Video
      • Brochure
      • Installation Specs
      • ASTM Standards
      • Submittal
    • Lateral Lining
      • Brochure
      • FAQ
      • Installation Specs
      • ASTM Standards
      • Articles
  • Main Menu
  • Home
  • Mainline
    • Sectional Inversion
      • Video
      • Brochure
      • FAQ
      • Installation Specs
      • ASTM Standards
      • Articles
    • CIPP Couplings
    • Lined Main Tap™
      • Video
      • Brochure
      • Installation Specs
    • End Seal
      • Video
      • Brochure
      • Installation Specs
  • Main Menu
  • Home
  • Manhole
    • CIPMH™ Chimney
      • Video
      • Brochure
      • FAQ
      • Installation Specs
      • Articles
    • Full Depth
      • Video
      • Brochure
      • FAQ
      • Submittal
    • End Seal
  • Main Menu
  • Home
  • Vac-A-Tee®
    • Vac-A-Tee®
      • Video
      • Brochure
      • FAQ
      • Installation Specs
      • Articles
    • Lined Main Tap™
      • Video
      • Brochure
      • Installation Specs
      • Articles
  • Main Menu
  • Home
  • Insignia™
    • O-Rings
    • End Seal Sleeve
      • Video
      • Brochure
      • Installation Specs
    • Hydrophilic Connection Hat
      • Brochure
    • Press Release
  • Main Menu
  • Home
  • Equipment
    • Power Cure™
      • Power Cure 3000
      • Power Cure 5000
    • Schwalm Robotic Systems
      • Brochures
      • Videos
    • Fabrication
  • Main Menu
  • Home
Back to Key FeaturesBack to Key Features

ASTM F2561

Purchase the full version of this standard by visiting the ASTM website here.

Significance and Use

This practice is for use by designers and specifiers, regulatory agencies, owners, and inspection organizations who are involved in the rehabilitation of sewer service laterals and its connection to the main through the use of a resin-impregnated tube installed within an existing sewer lateral. As for any practice, modifications may be required for specific job conditions.

  1. Scope

    1. This practice covers requirements and test methods for the reconstruction of a sewer service lateral pipe having an inner diameter of 3 to 12 in. and its connection to the main pipe having an inner diameter of 6 to 24 in. without excavation. The lateral pipe is accessed remotely from the main pipe and from a lateral cleanout. This will be accomplished by the installation of a resin impregnated one-piece main and lateral cured in-place lining (MLCIPL) by means of air or water inflation and inversion. The MLCIPL is pressed against the host pipe by pressurizing a bladder and is held in place until the thermoset resins have cured. When cured, the MLCIPL shall be a continuous, one piece, tight fitting, corrosion resistant lining extending over a predetermined length of the lateral pipe and the adjacent section of the main pipe providing a verifiable non-leaking structural connection and seal.

    2. The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are provided for information only.

    3. There is no similar or equivalent ISO Standard.

    4. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Particular attention is drawn to those safety regulations and requirements involving entering into and working in confined spaces.

  2. Referenced Documents

    • D1600 Terminology for Abbreviated Terms Relating to Plastics
    • D3681 Test Method for Chemical Resistance of "Fiberglass" (Glass-Fiber-Reinforced Thermosetting-Resin) Pipe in a Deflected Condition
    • D5813 Specification for Cured-In-Place Thermosetting Resin Sewer Piping Systems
    • D618 Practice for Conditioning Plastics for Testing
    • D790 Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials
    • F1216 Practice for Rehabilitation of Existing Pipelines and Conduits by the Inversion and Curing of a Resin-Impregnated Tube
    • F412 Terminology Relating to Plastic Piping Systems
    • Recommended Specifications for Sewer Collection System Rehabilitation

Index Terms

ambient cure; continuous; cured-in-place pipe; epoxy; felt; hydrophilic o-rings; inflation; inversion; knit; lateral identification; lateral pipe; lateral tube; launcher; liner/bladder assembly; main pipe; main sheet; main to lateral connection; MLCIPL; one-piece; resin; sewer lateral lines; sheet; steam cure; TEE; textile sheet; textile tube; transition; translucent bladder; tube; vacuum impregnate; WYE; ICS Number Code 93.030 (External sewerage systems)

DOI:

10.1520/F2561-06

For a copy of the ASTM F2561 Standard please visit www.astm.org

LMK Technologies - Centrally located in Ottawa, IL USA since 1993 P: 815.433.1275 F: 815.433.0107

The products manufactured by LMK Technologies, Inc. are made in the United States of America.

©2008 LMK Technologies all rights reserved contact home sitemap